summaryrefslogtreecommitdiff
blob: 10528f59a3d6f3118a6e64f228c8793075a1d45b (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
# Copyright 1999-2008 Gentoo Foundation
# Distributed under the terms of the GNU General Public License v2
# $Header: /var/cvsroot/gentoo-x86/sys-power/apcupsd/apcupsd-3.14.3.ebuild,v 1.1 2008/05/08 19:37:30 tantive Exp $

WEBAPP_MANUAL_SLOT="yes"
inherit eutils webapp

DESCRIPTION="APC UPS daemon with integrated tcp/ip remote shutdown"
HOMEPAGE="http://www.apcupsd.org/"
SRC_URI="mirror://sourceforge/apcupsd/${P}.tar.gz"

LICENSE="GPL-2"
SLOT="0"
KEYWORDS="~alpha ~amd64 ~ppc ~sparc ~x86 ~x86-fbsd"
IUSE="doc snmp usb cgi ncurses nls gnome"

DEPEND="doc? ( virtual/tetex dev-tex/latex2html )
	cgi? ( >=media-libs/gd-1.8.4 )
	ncurses? ( sys-libs/ncurses )
	nls? ( sys-devel/gettext )
	snmp? ( net-analyzer/net-snmp )
	gnome? ( >=x11-libs/gtk+-2.4.0
		>=dev-libs/glib-2.0
		>=gnome-base/gconf-2.0 )"
RDEPEND="${DEPEND}
	virtual/mta"

pkg_setup() {
	use cgi && webapp_pkg_setup
}

src_unpack() {
	unpack ${A}
	cd "${S}"
	epatch "${FILESDIR}"/${PV}/apcupsd.in.patch
	epatch "${FILESDIR}"/${PV}/etc.patch
	epatch "${FILESDIR}"/${PV}/hal-ups-policy.patch
}

src_compile() {
	local myconf
	use cgi && myconf="${myconf} --enable-cgi --with-cgi-bin=${MY_CGIBINDIR}"
	use usb && myconf="${myconf} --with-upstype=usb --with-upscable=usb --enable-usb --without-dev"
	use !usb && myconf="${myconf} --with-upstype=apcsmart --with-upscable=smart --disable-usb"

	# We force the DISTNAME to gentoo so it will use gentoo's layout also
	# when installed on non-linux systems.
	DISTNAME=gentoo APCUPSD_MAIL=/usr/sbin/sendmail ./configure \
		--prefix=/usr \
		--sbindir=/sbin \
		--mandir=/usr/share/man \
		--sysconfdir=/etc/apcupsd \
		--with-pwrfail-dir=/etc/apcupsd \
		--with-lock-dir=/var/lock \
		--with-pid-dir=/var/run \
		--with-log-dir=/var/log \
		--with-nis-port=3551 \
		--enable-net \
		$(use_enable ncurses powerflute) \
		$(use_enable snmp net-snmp) \
		$(use_enable nls) \
		$(use_enable gnome gapcmon) \
		${myconf} \
		|| die
	emake -j1 || die "emake failed"

	if use doc; then
		einfo "Building full documentation..."
		cd "${S}"/doc/latex
		make texcheck tex web pdf
	fi
}

src_install() {
	use cgi && webapp_src_preinst

	emake DESTDIR="${D}" install || die "installed failed"
	rm -f "${D}"/etc/init.d/halt

	insinto /etc/apcupsd
	newins examples/safe.apccontrol safe.apccontrol

	dodoc ChangeLog* ReleaseNotes
	mv doc/apctest.man doc/apctest.8; doman doc/apctest.8

	if use doc; then
		einfo "Installing full documentation..."
		newdoc doc/latex/apcupsd.pdf manual.pdf
		dohtml -r doc/latex/apcupsd/*
	fi

	if use cgi; then
		mv "${D}"/etc/apcupsd/apcupsd.css "${D}""${MY_CGIBINDIR}"
		webapp_src_install
	fi

	rm "${D}"/etc/init.d/apcupsd
	newinitd "${FILESDIR}/${PV}/${PN}.initd" "${PN}"
}

pkg_postinst() {
	if use cgi; then
		elog If you are upgrading from a previous version, please note
		elog that the CGI interface is now installed using webapp-config.
		elog /var/www/apcupsd is no longer present.
		webapp_pkg_postinst
	fi

	elog ""
	elog "Since version 3.14.0 you can use multiple apcupsd instances to"
	elog "control more than one UPS in a single box."
	elog "To do this, create a link between /etc/init.d/apcupsd to a new"
	elog "/etc/init.d/apcupsd.something, and it will then load the"
	elog "configuration file at /etc/apcupsd/something.conf."
	elog ""
}

pkg_prerm() {
	use cgi && webapp_pkg_prerm
}